Here is some information from an internet based encyclopedia site regarding electrical motors and motor contacts which might be of interest.  However, please be advised that this content is informational only and should not be construed as official or formal advice with respect to motor contact.   Please remember one should never undertake or proceed on projects related to electrical contact kits or motor contacts without a skilled and licensed professional.

 

If you are interested in ordering Hoyt Contact Kits, please click here

For information on Hoyt Contacts, please visit www.hoytcontacts.com.

To return to the main Motor Contacts.com page, click here

 

Speed control

 

Generally speaking the rotational speed of a DC motor is proportional to the voltage applied to it, and the torque is proportional to the current. Speed control can be achieved by variable battery tappings, variable supply voltage, resistors or electronic controls. The direction of a wound field DC motor can be changed by reversing either the field or armature connections but not both, this is commonly done with a special set of contactors (direction contactors).

 

Effective voltage can be varied by inserting a series resistor or by an electronically-controlled switching device made of thyristors, transistors, or, historically, mercury arc rectifiers. In a circuit known as a chopper, the average voltage applied to the motor is varied by switching the supply voltage very rapidly. As the "on" to "off" ratio is varied to alter the average applied voltage, the speed of the motor varies. The rapid switching wastes less energy than series resistors. Output filters smooth the average voltage applied to the motor and reduce motor noise.

 

Since the series-wound DC motor develops its highest torque at low speed, it is often used in traction applications such as electric locomotives, and trams. Another application is starter motors for petrol and small diesel engines. Series motors must never be used in applications where the drive can fail (such as belt drives). As the motor accelerates the armature (and hence field) current reduces. The reduction in field causes the motor to speed up (see 'weak field' in the last section). As a consequence the motor's speed tends to infinity, but the motor will destroy itself before it spins that fast.

 

One interesting method of speed control of a DC motor was Ward-Leonard Control. Although it is a method of controlling a DC motor (usually a shunt or compound wound). It was developed as a method of providing a speed controlled motor from an AC supply, though it was not without its advantages in DC schemes. The AC supply is used to drive an AC motor, usually an induction motor that drives a DC generator or dynamo. The DC output from the armature is directly connected to the armature of the DC motor (usually of identical construction). The shunt field windings of both DC machines are excited via a variable resistor from the generator’s armature. This variable resistor provides extremely good speed control from standstill to full speed, and consistent torque. This method of control was the defacto method from its development until it was superseded by solid state thyristor systems. It found service in almost any environment where good speed control was required, from passenger lifts through to large mine pit head winding gear and even industrial process machinery and electric cranes. Its principle disadvantage was that 3 machines were required to implement a scheme (5 in very large installations as the DC machines were often duplicated and controlled by a tandem variable resistor). In many applications, the motor-generator set was often left permanently running to avoid the delays that would otherwise be necessitated by starting it up as required. There are numerous legacy Ward-Leonard installations still in service today.

 

 

Universal motors

 

A variant of the wound field DC motor is the universal motor. The name derives from the fact that it may use AC or DC supply current, although in practice they are nearly always used with AC supplies. The principle is that in a wound field DC motor the current in both the field and the armature (and hence the resultant magnetic fields) will alternate (reverse polarity) at the same time, and hence the mechanical force generated is always in the same direction. In practice the motor must be specially designed to cope with the AC current (impedance must be taken into account as must the pulsating force), and the resultant motor is generally less efficient than an equivalent pure DC motor. The maximum output of universal motors is limited, and motors exceeding one kilowatt are rarely operated on commercial power frequency.

 

The advantage of the universal motor is that AC supplies may be used on motors which have the typical characteristics of DC motors, specifically high starting torque and very compact design if high running speeds are used. The negative aspect is the maintenance and short life problems caused by the commutator. As a result such motors are usually used in AC devices such as food mixers and power tools which are only used intermittently. Continuous speed control of a universal motor running on AC is very easily accomplished using a thyristor circuit while stepped speed control can be accomplished using multiple taps on the field coil. Household blenders that advertise many speeds frequently combine a field coil with several taps and a diode that can be inserted in series with the motor (causing the motor to run on half-wave DC with half the RMS voltage of the AC power line).

 

Unlike AC motors, universal motors can easily exceed one revolution per cycle of the mains current. This makes them useful for appliances such as blenders, vacuum cleaners, and hair dryers where high-speed operation is desired. Many vacuum cleaner and weed trimmer motors will exceed 10,000 RPM, Dremel and other similar miniature grinders will often exceed 30,000 RPM. A theoretical universal motor allowed to operate with no mechanical load will overspeed, which may damage it. In real life, though, various bearing frictions, armature "windage", and the load of any integrated cooling fan all act to prevent overspeed.

 

With the very low cost of semiconductor rectifiers, some applications that would have previously used a universal motor now use a pure DC motor, usually with a permanent magnet field. This is especially true if the semiconductor circuit is also used for variable-speed control.

 

The advantages of the universal motor and alternating-current distribution made installation of a low-frequency traction current distribution system economical for some railway installations. At low enough frequencies, the motor performance is approximately the same as if the motor were operating on DC. Frequencies as low as 16 2/3 Hertz were employed.

 

 

AC motors

 

A typical AC motor consists of two parts:

 

An outside stationary stator having coils supplied with AC current to produce a rotating magnetic field, and;

An inside rotor attached to the output shaft that is given a torque by the rotating field.

There are two fundamental types of AC motor depending on the type of rotor used:

 

The synchronous motor, which rotates exactly at the supply frequency or a submultiple of the supply frequency, and;

The induction motor, which turns slightly slower, and typically (though not necessarily always) takes the form of the squirrel cage motor.

The rotating magnetic field principle, though commonly credited to Nikola Tesla in 1882 or thereabouts, was employed by scientists such as Michael Faraday and James Clerk Maxwell in the 1820s. Tesla, however, exploited the principle to design a unique two-phase induction motor in 1883. Michael von Dolivo-Dobrowlsky invented the first modern three-phase "cage-rotor" in 1890. Introduction of the motor from 1888 onwards initiated what is known as the Second Industrial Revolution, making possible the efficient generation and long distance distribution of electrical energy using the alternating current transmission system, also of Tesla's invention (1888)[1]. The first successful commercial three phase generation and long distance transmission system was designed by Almerian Decker at Mill Creek No. 1 [2] in Redlands California.[3]

 

 

Three-phase AC induction motors

 

Three phase AC induction motors rated 1 Hp (750 W) and 25 W with small motors from CD player, toy and CD/DVD drive reader head traverseWhere a polyphase electrical supply is available, the three-phase (or polyphase) AC induction motor is commonly used, especially for higher-powered motors. The phase differences between the three phases of the polyphase electrical supply create a rotating electromagnetic field in the motor.

 

Through electromagnetic induction, the rotating magnetic field induces a current in the conductors in the rotor, which in turn sets up a counterbalancing magnetic field that causes the rotor to turn in the direction the field is rotating. The rotor must always rotate slower than the rotating magnetic field produced by the polyphase electrical supply; otherwise, no counterbalancing field will be produced in the rotor.

 

Induction motors are the workhorses of industry and motors up to about 500 kW in output are produced in highly standardized frame sizes, making them nearly completely interchangeable between manufacturers (although European and North American standard dimensions are different). Very large synchronous motors are made up to tens of thousands of kilowatts output, for pipeline compressors and wind-tunnel drives.

 

There are two types of rotors used in induction motors.

 

Squirrel Cage rotors: Most common AC motors use the squirrel cage rotor, which will be found in virtually all domestic and light industrial alternating current motors. The squirrel cage takes its name from its shape - a ring at either end of the rotor, with bars connecting the rings running the length of the rotor. It is typically cast aluminum or copper poured between the iron laminates of the rotor, and usually only the end rings will be visible. The vast majority of the rotor currents will flow through the bars rather than the higher-resistance and usually varnished laminates. Very low voltages at very high currents are typical in the bars and end rings; high efficiency motors will often use cast copper in order to reduce the resistance in the rotor.

 

In operation, the squirrel cage motor may be viewed as a transformer with a rotating secondary - when the rotor is not rotating in sync with the magnetic field, large rotor currents are induced; the large rotor currents magnetize the rotor and interact with the stator's magnetic fields to bring the rotor into synchronization with the stator's field. An unloaded squirrel cage motor at synchronous speed will only consume electrical power to maintain rotor speed against friction and resistance losses; as the mechanical load increases, so will the electrical load - the electrical load is inherently related to the mechanical load. This is similar to a transformer, where the primary's electrical load is related to the secondary's electrical load.

 

This is why, as an example, a squirrel cage blower motor may cause the lights in a home to dim as it starts, but doesn't dim the lights when its fanbelt (and therefore mechanical load) is removed. Furthermore, a stalled squirrel cage motor (overloaded or with a jammed shaft) will consume current limited only by circuit resistance as it attempts to start. Unless something else limits the current (or cuts its off completely) overheating and destruction of the winding insulation is the likely outcome.

 

Virtually every washing machine, dishwasher, standalone fan, record player, etc. uses some variant of a squirrel cage motor.

 

Wound Rotor: An alternate design, called the wound rotor, is used when variable speed is required. In this case, the rotor has the same number of poles as the stator and the windings are made of wire, connected to slip rings on the shaft. Carbon brushes connect the slip rings to an external controller such as a variable resistor that allows changing the motor's slip rate. In certain high-power variable speed wound-rotor drives, the slip-frequency energy is captured, rectified and returned to the power supply through an inverter.

 

Compared to squirrel cage rotors, wound rotor motors are expensive and require maintenance of the slip rings and brushes, but they were the standard form for variable speed control before the advent of compact power electronic devices. Transistorized inverters with variable frequency drive can now be used for speed control and wound rotor motors are becoming less common. (Transistorized inverter drives also allow the more-efficient three-phase motors to be used when only single-phase mains current is available, but this is never used in house hold appliances, because it can cause electrical interference and because of high power requirements.)

 

Several methods of starting a polyphase motor are used. Where the large inrush current and high starting torque can be permitted, the motor can be started across the line, by applying full line voltage to the terminals. Where it is necessary to limit the starting inrush current (where the motor is large compared with the short-circuit capacity of the supply), reduced voltage starting using either series inductors, an autotransformer, thyristors, or other devices are used. A technique sometimes used is star-delta starting, where the motor coils are initially connected in wye for acceleration of the load, then switched to delta when the load is up to speed. This technique is more common in Europe than in North America. Transistorized drives can directly vary the applied voltage as required by the starting characteristics of the motor and load.

 

This type of motor is becoming more common in traction applications such as locomotives, where it is known as the asynchronous traction motor.

 

The speed of the AC motor is determined primarily by the frequency of the AC supply and the number of poles in the stator winding, according to the relation:

 

Ns = 120F / p

where

 

Ns = Synchronous speed, in revolutions per minute

F = AC power frequency

p = Number of poles per phase winding

Actual RPM for an induction motor will be less than this calculated synchronous speed by an amount known as slip that increases with the torque produced. With no load the speed will be very close to synchronous. When loaded, standard motors have between 2-3% slip, special motors may have up to 7% slip, and a class of motors known as torque motors are rated to operate at 100% slip (0 RPM/full stall).

 

The slip of the AC motor is calculated by:

 

S = (Ns − Nr) / Ns

where

 

Nr = Rotational speed, in revolutions per minute.

S = Normalised Slip, 0 to 1.

As an example, a typical four-pole motor running on 60 Hz might have a nameplate rating of 1725 RPM at full load, while its calculated speed is 1800.

 

The speed in this type of motor has traditionally been altered by having additional sets of coils or poles in the motor that can be switched on and off to change the speed of magnetic field rotation. However, developments in power electronics mean that the frequency of the power supply can also now be varied to provide a smoother control of the motor speed.

 

 

Three-phase AC synchronous motors

If connections to the rotor coils of a three-phase motor are taken out on slip-rings and fed a separate field current to create a continuous magnetic field (or if the rotor consists of a permanent magnet), the result is called a synchronous motor because the rotor will rotate in synchronism with the rotating magnetic field produced by the polyphase electrical supply.

 

A synchronous motor can also be used as an alternator.

 

Nowadays, synchronous motors are frequently driven by transistorized variable frequency drives. This greatly eases the problem of starting the massive rotor of a large synchronous motor. They may also be started as induction motors using a squirrel-cage winding that shares the common rotor: once the motor reaches synchronous speed, no current is induced in the squirrel-cage winding so it has little effect on the synchronous operation of the motor, aside from stabilizing the motor speed on load changes.

 

Synchronous motors are occasionally used as traction motors; the TGV may be the best-known example of such use.

 

 

Single-phase AC induction motors

Three-phase motors inherently produce a rotating magnetic field. However, when only single-phase power is available, the rotating magnetic field must be produced using other means. Several methods are commonly used.

 

A common single-phase motor is the shaded-pole motor, which is used in devices requiring low torque, such as electric fans or other small household appliances. In this motor, small single-turn copper "shading coils" create the moving magnetic field. Part of each pole is encircled by a copper coil or strap; the induced current in the strap opposes the change of flux through the coil (Lenz's Law), so that the maximum field intensity moves across the pole face on each cycle, thus producing the required rotating magnetic field.

 

Another common single-phase AC motor is the split-phase induction motor, commonly used in major appliances such as washing machines and clothes dryers. Compared to the shaded pole motor, these motors can generally provide much greater starting torque by using a special startup winding in conjunction with a centrifugal switch.

 

In the split-phase motor, the startup winding is designed with a higher resistance than the running winding. This creates an LR circuit which slightly shifts the phase of the current in the startup winding. When the motor is starting, the startup winding is connected to the power source via a set of spring-loaded contacts pressed upon by the not-yet-rotating centrifugal switch. The starting winding is wound with fewer turns of smaller wire than the main winding, so it has a lower inductance (L) and higher resistance (R). The lower L/R ratio creates a small phase shift, not more than about 30 degrees, between the flux due to the main winding and the flux of the starting winding. The starting direction of rotation may be reversed simply by exchanging the connections of the startup winding relative to the running winding.

 

The phase of the magnetic field in this startup winding is shifted from the phase of the mains power, allowing the creation of a moving magnetic field which starts the motor. Once the motor reaches near design operating speed, the centrifugal switch activates, opening the contacts and disconnecting the startup winding from the power source. The motor then operates solely on the running winding. The starting winding must be disconnected since it would increase the losses in the motor.

 

In a capacitor start motor, a starting capacitor is inserted in series with the startup winding, creating an LC circuit which is capable of a much greater phase shift (and so, a much greater starting torque). The capacitor naturally adds expense to such motors.

 

Another variation is the Permanent Split-Capacitor (PSC) motor (also known as a capacitor start and run motor). This motor operates similarly to the capacitor-start motor described above, but there is no centrifugal starting switch and the second winding is permanently connected to the power source. PSC motors are frequently used in air handlers, fans, and blowers and other cases where a variable speed is desired. By changing taps on the running winding but keeping the load constant, the motor can be made to run at different speeds. Also provided all 6 winding connections are available separately a 3 phase motor can be converted to a capactor start and run motor by commoning two of the windings and connecting the third via a capacitor to act as a start winding.

 

Repulsion motors are wound-rotor single-phase AC motors that are similar to universal motors. In a repulsion motor, the armature brushes are shorted together rather than connected in series with the field. Several types of repulsion motors have been manufactured, but the repulsion-start induction-run (RS-IR) motor has been used most frequently. The RS-IR motor has a centrifugal switch that shorts all segments of the commutator so that the motor operates as an induction motor once it has been accelerated to full speed. RS-IR motors have been used to provide high starting torque per ampere under conditions of cold operating temperatures and poor source voltage regulation. Few repulsion motors of any type are sold as of 2006.

 

 

Single-phase AC synchronous motors

 

Small single-phase AC motors can also be designed with magnetized rotors (or several variations on that idea). The rotors in these motors do not require any induced current so they do not slip backward against the mains frequency. Instead, they rotate synchronously with the mains frequency. Because of their highly accurate speed, such motors are usually used to power mechanical clocks, audio turntables, and tape drives; formerly they were also much used in accurate timing instruments such as strip-chart recorders or telescope drive mechanisms. The shaded-pole synchronous motor is one version.

 

Because inertia makes it difficult to instantly accelerate the rotor from stopped to synchronous speed, these motors normally require some sort of special feature to get started. Various designs use a small induction motor (which may share the same field coils and rotor as the synchronous motor) or a very light rotor with a one-way mechanism (to ensure that the rotor starts in the "forward" direction).

 

 

Torque motors

 

A torque motor is a specialized form of induction motor which is capable of operating indefinitely at stall (with the rotor blocked from turning) without damage. In this mode, the motor will apply a steady torque to the load (hence the name). A common application of a torque motor would be the supply- and take-up reel motors in a tape drive. In this application, driven from a low voltage, the characteristics of these motors allow a relatively-constant light tension to be applied to the tape whether or not the capstan is feeding tape past the tape heads. Driven from a higher voltage, (and so delivering a higher torque), the torque motors can also achieve fast-forward and rewind operation without requiring any additional mechanics such as gears or clutches.

 

 

Stepper motors

 

Main article: Stepper motor

Closely related in design to three-phase AC synchronous motors are stepper motors, where an internal rotor containing permanent magnets or a large iron core with salient poles is controlled by a set of external magnets that are switched electronically. A stepper motor may also be thought of as a cross between a DC electric motor and a solenoid. As each coil is energized in turn, the rotor aligns itself with the magnetic field produced by the energized field winding. Unlike a synchronous motor, in its application, the motor may not rotate continuously; instead, it "steps" from one position to the next as field windings are energized and deenergized in sequence. Depending on the sequence, the rotor may turn forwards or backwards.

 

Simple stepper motor drivers entirely energize or entirely deenergize the field windings, leading the rotor to "cog" to a limited number of positions; more sophisticated drivers can proportionally control the power to the field windings allowing the rotors to position "between" the "cog" points and thereby rotate extremely smoothly. Computer controlled stepper motors are one of the most versatile forms of positioning systems, particularly when part of a digital servo-controlled system.

 

 

Brushless DC motors

 

Main article: Brushless DC electric motor

Many of the limitations of the classic commutator DC motor are due to the need for brushes to press against the commutator. This creates friction. At higher speeds, brushes have increasing difficulty in maintaining contact. Brushes may bounce off the irregularities in the commutator surface, creating sparks. This limits the maximum speed of the machine. The current density per unit area of the brushes limits the output of the motor. The imperfect electric contact also causes electrical noise. Brushes eventually wear out and require replacement, and the commutator itself is subject to wear and maintenance. The commutator assembly on a large machine is a costly element, requiring precision assembly of many parts.

 

These problems are eliminated in the brushless motor. In this motor, the mechanical "rotating switch" or commutator/brushgear assembly is replaced by an external electronic switch synchronised to the motor's position. Brushless motors are typically 85-90% efficient whereas DC motors with brushgear are typically 10% less efficient.

 

Midway between ordinary DC motors and stepper motors lies the realm of the brushless DC motor. Built in a fashion very similar to stepper motors, these often use a permanent magnet external rotor, three phases of driving coils, one or more Hall effect devices to sense the position of the rotor, and the associated drive electronics. The coils are activated, one phase after the other, by the drive electronics as cued by the signals from the Hall effect sensors. In effect, they act as three-phase synchronous motors containing their own variable frequency drive electronics. A specialized class of brushless DC motor controllers utilize EMF feedback through the main phase connections instead of Hall effect sensors to determine position and velocity. These motors are used extensively in electric radio-controlled vehicles.

 

Brushless DC motors are commonly used where precise speed control is necessary, computer disk drives or in video cassette recorders the spindles within CD, CD-ROM (etc.) drives, and mechanisms within office products such as fans, laser printers and photocopiers. They have several advantages over conventional motors:

 

Compared to AC fans using shaded-pole motors, they are very efficient, running much cooler than the equivalent AC motors. This cool operation leads to much-improved life of the fan's bearings.

Without a commutator to wear out, the life of a DC brushless motor can be significantly longer compared to a DC motor using brushes and a commutator. Commutation also tends to cause a great deal of electrical and RF noise; without a commutator or brushes, a brushless motor may be used in electrically sensitive devices like audio equipment or computers.

The same Hall effect devices that provide the commutation can also provide a convenient tachometer signal for closed-loop control (servo-controlled) applications. In fans, the tachometer signal can be used to derive a "fan okay" signal.

The motor can be easily synchronized to an internal or external clock, leading to precise speed control.

Modern DC brushless motors range in power from a fraction of a watt to many kilowatts. Larger brushless motors up to about 100 kW rating are used in electric vehicles. They also find significant use in high-performance electric model aircraft.

 

 

Coreless DC motors

 

Nothing in the design of any of the motors described above requires that the iron (steel) portions of the rotor actually rotate; torque is only exerted on the windings of the electromagnets. Taking advantage of this fact is the coreless DC motor, a specialized form of a brush DC motor. Optimized for rapid acceleration, these motors have a rotor that is constructed without any iron core. The rotor can take the form of a winding-filled cylinder inside the stator magnets, a basket surrounding the stator magnets, or a flat pancake (possibly formed on a printed wiring board) running between upper and lower stator magnets. The windings are typically stabilized by being impregnated with epoxy resins.

 

Because the rotor is much lighter in weight (mass) than a conventional rotor formed from copper windings on steel laminations, the rotor can accelerate much more rapidly, often achieving a mechanical time constant under 1 ms. This is especially true if the windings use aluminum rather than the heavier copper. But because there is no metal mass in the rotor to act as a heat sink, even small coreless motors must often be cooled by forced air.

 

These motors were commonly used to drive the capstan(s) of magnetic tape drives and are still widely used in high-performance servo-controlled systems.

 

 

Linear motors

 

A linear motor is essentially an electric motor that has been "unrolled" so that instead of producing a torque (rotation), it produces a linear force along its length by setting up a traveling electromagnetic field.

 

Linear motors are most commonly induction motors or stepper motors. You can find a linear motor in a maglev (Transrapid) train, where the train "flies" over the ground.


 

If you are interested in ordering Hoyt Contact Kits, please click here

For information on Hoyt Contacts, please visit www.hoytcontacts.com.

To return to the main Motor Contacts.com page, click here